300-615 無料問題集「Cisco Troubleshooting Cisco Data Center Infrastructure」
Drag and Drop Question
Drag and drop the commands from the left onto the correct categories on the right.
![](https://www.jpntest.com/uploads/imgs/300-615 V16.35/img_81.jpg)
Drag and drop the commands from the left onto the correct categories on the right.
![](https://www.jpntest.com/uploads/imgs/300-615 V16.35/img_81.jpg)
正解:
![](https://www.jpntest.com/uploads/imgs/300-615 V16.35/img_83.jpg)
A customer configures HSRP between two data centers that are interconnected with OTV. The configuration succeeds, but traffic between two ESXi virtual hosts on the same site is routed suboptimally through the OTV overlay. Which two actions optimize the traffic? (Choose two.)
正解:A、E
解答を投票する
解説: (JPNTest メンバーにのみ表示されます)
Refer to the exhibit. An engineer is troubleshooting a VSAN membership issue on switch N9K_1 where vfc 13 is associated to VSAN 1 instead of VSAN 10. The Cisco UCS, N9K_2, and QoS configurations have been verified. Which additional configuration on N9K_1 must be implemented to resolve the issue?
![](https://www.jpntest.com/uploads/imgs/300-615 V16.35/img_343.jpg)
![](https://www.jpntest.com/uploads/imgs/300-615 V16.35/img_344.jpg)
![](https://www.jpntest.com/uploads/imgs/300-615 V16.35/img_346.jpg)
![](https://www.jpntest.com/uploads/imgs/300-615 V16.35/img_343.jpg)
![](https://www.jpntest.com/uploads/imgs/300-615 V16.35/img_344.jpg)
![](https://www.jpntest.com/uploads/imgs/300-615 V16.35/img_346.jpg)
正解:A
解答を投票する
Refer to the exhibit. An integration issue occurs between the Cisco Intersight and Cisco UCS C240 server. The requirements are to install the server OS through virtual media directly from Cisco Intersight, and to be able to perform the task from HQ. However, the 10.1.1.0/24 network is not reachable from HQ. Which action must be taken on UCS C240 to resolve the issue?
![](https://www.jpntest.com/uploads/imgs/300-615 V16.35/img_306.jpg)
![](https://www.jpntest.com/uploads/imgs/300-615 V16.35/img_306.jpg)
正解:B
解答を投票する
Drag and Drop Question
A firmware upgrade on a fabric interconnect fails. A bootflash contains a valid image. Drag and drop the recovery steps from the left onto the correct order on the right.
![](https://www.jpntest.com/uploads/imgs/300-615 V16.35/img_84.jpg)
A firmware upgrade on a fabric interconnect fails. A bootflash contains a valid image. Drag and drop the recovery steps from the left onto the correct order on the right.
![](https://www.jpntest.com/uploads/imgs/300-615 V16.35/img_84.jpg)
正解:
![](https://www.jpntest.com/uploads/imgs/300-615 V16.35/img_86.jpg)
You have an ACI environment with three APICs, two spine switches, and four-leaf switches. You wipe and reboot all APICs first then leaf and spine switches one- by-one and successfully go through the Initial Setuo dialogue on the APIC 1 CIMC KVM console. When you log in to the APIC1 WebGUI, you notice that you do not see any directly connected leaf switches being discovered under Fabric > Inventory > Fabric Membership. What is the cause of the issue?
正解:B
解答を投票する
解説: (JPNTest メンバーにのみ表示されます)