A4040-109 無料問題集「IBM Assessment: Power Systems Virtualization Technical Support for AIX and Linux -v2」

An existing machine is configured with redundant VIO Servers with SEA failover. A number of VLANs are already configured and used by the hosted client LPARs. Two additional VLANs are required to be added to the deployment to support new growth.
An administrator uses a DLPAR operation to add the additional VLANs to the existing Virtual Ethernet adapters. The attempt failed. They have updated the LPAR profile for both VIO Servers. Next they shutdown one of the VIO Servers and attempt to reactivate the LPAR. The following error is displayed:
"HSCL0282 The virtual Ethernet adapter in virtual I/O slot 11 can't be defined because the partition with ID 2 already defines a trunk adapter in its virtual I/O slot 11. Please modify the profile accordingly and reactivate the partition."
What is the cause of the failure?

A dedicated LPAR has two dedicated Fibre Channel HBAs assigned to it.
In order to reduce the amount of hardware, the LPAR will be migrated to a currently
running VIO server.
The administrator collects some server performance from the VIO server and notices that the I/O peaks at 5.5Gbits and runs at an average of 4Gbits per second.
The VIO Server runs two dual port 8Gbit FCS cards, so the load is not affected by other LPARS on the VIO Server.
Which of the following is the most cost-efficient configuration for the VIO client?

What is a major benefit for using LHEA instead of an SEA?

An administrator needs to add additional LPARs to a Power 770 server, but all of the
available memory on the system is currently assigned to existing LPARs and is continually utilized.
What solution can the administrator implement on the system to add the LPARs?

A number of POWER7 servers have been ordered to replace an existing infrastructure of POWER4 machines. All existing LPARs will be manually recreated on the new machines, preserving the installed operating systems.
An administrator is planning to attach the POWER7 machines to the subnet, allowing the LPARs to keep their hostname and IP addresses. The NIM server that will be used to restore the LPARs on the new machines allows its clients it initiate NIM client commands.
What needs to be considered to preserve the ability to restore an existing LPAR on the new infrastructure?

Certain configurations of Power 770 and Power 780 servers can be ordered with multiple IVE adapters. When designing a configuration to provide improved network availability what fact should be observed as a risk?

An administrator adds a new virtual target device to a vhost adapter that already had target devices on it. The client LPAR does not detect the new disk and the following error has been logged in the errlog:

What is the most likely cause for this situation?

An administrator would like to create AIX 5.2 Workload Partitions (WPARs) on a new POWER7 system.
Which of the following is the minimum needed to achieve this?

The wlmstat -@ 2 command has been run from a global environment with the following results:

What action can an administrator take to set limits, so that both server1 and server2 use the same amount of CPU resources?

An administrator tries to dynamically increase the processor capacity entitlement of LPAR1 from 1.0 to 2.0. The current entitlement is 1.0 and the maximum is set to 3.0.
The operation fails. When the administrator adds up the number of processors in use by the currently running LPARs, there are 4 processors available. The administrator also notes that LPAR2 is inactive.
What is the cause of this failure?

弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

オンラインサポート時間:( UTC+9 ) 9:00-24:00
月曜日から土曜日まで

サポート:現在連絡