C4040-109 無料問題集「IBM Virtualization Technical Support for AIX and Linux - v2」

Consider the following extract from the command Ismap -all -npiv -fmt:
vfchost0:U9119.FHA.44ABCDE-V2-C642:47:: :NOT_LOGGED_IN;fcs2:U5803.001.9112345-P2-C7-T1:0:4::
vfchost1:U9119.FHA44ABCDE-V2C643:48:lpar02AIX:LOGGED_IN:fcs2:U5803.001.9112345-P2-C7-T1:5:a:fcsO:U9119.FHA
44ABCDE-V48-C8-T1
From this information which of the following statements is true?

A WPAR environment is being planned. The WPARs will run applications which are to be completely contained since the network is insecure. How would this be structured?

When planning for virtual disk redundancy on an AIX LPAR, which solution would provide the highest availability?

While reactivating client LPARs following a scheduled power down, some LPARs have lost visibility to their NPIV-allocated SAN LUNs. On investigation it appears the WWNs have changed on the problem LPARs. What is the most likely cause for the change in WWN?

An administrator has a Power 720 with 64GB of memory and Active Memory Expansion (AME).
An LPAR has only 10GB of memory available and an application has been sized at 15GB of memory. The administrator runs amepat to determine an efficient expansion factor. Based on the output, an expansion factor of 1.6 has been chosen.
How should this be configured in the LPAR?

What tool can an architect use to determine which is the smallest POWER7 server that will provide equal or better overall performance than a POWER5 570?

A system has 2 LPARs and a VIO Server with networking configured as follows:

LPAR1 and LPAR2 are unable to communicate with external systems. What should be done to allow them to access the external network?

An existing machine is configured with redundant VIO Servers with SEA failover. A number of VLANs are already configured and used by the hosted client LPARs. Two additional VLANs are required to be added to the deployment to support new growth.
An administrator uses a DLPAR operation to add the additional VLANs to the existing Virtual Ethernet adapters. The attempt failed. They have updated the LPAR profile for both VIO Servers. Next they shutdown one of the VIO Servers and attempt to reactivate the LPAR. The following error is displayed:
"HSCL0282 The virtual Ethernet adapter in virtual I/O slot 11 can't be defined because the partition with ID 2 already defines a trunk adapter in its virtual I/O slot 11. Please modify the profile accordingly and reactivate the partition."
What is the cause of the failure?

An administrator would like to install a new Fix Pack on an existing VIO server. The Fix Pack has been mounted using NFS on /mnt. Which command should the administrator use to achieve this?

An administrator is preparing to upgrade the environment's dual Virtual I/O servers (VIOS) from V1.2 to V2.1
What must considered in preparation for this upgrade?

弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

オンラインサポート時間:( UTC+9 ) 9:00-24:00
月曜日から土曜日まで

サポート:現在連絡