D-SNC-DY-00 無料問題集「EMC Dell SONiC Deploy」

How many times must BGP be configured when running symmetric IRB with two VFRs?

解説: (JPNTest メンバーにのみ表示されます)
Use the simulator to perform the following configuration task.
1. Map a single-tagged CVLAN 100 to SVLAN 200 translation on PE
switch interface Eth1/1.
2. Map a double-tagged VLAN packet with an outer CVLAN 100 and an
inner dot1q 200 to SVLAN 300 translation on PE switch interface
Eth1/2.
The necessary VLANs and VLAN stacking have already been configured.
正解:
see the explanation for all step by step solution with all explanation.
Explanation:
Here are the steps to configure the required VLAN translations on a Dell SONiC switch:
* Map a Single-Tagged CVLAN 100 to SVLAN 200 on Interface Eth1/1:
sonic# configure terminal
sonic(config)# interface Ethernet1/1
sonic(config-if-Ethernet1/1)# switchport mode trunk
sonic(config-if-Ethernet1/1)# switchport vlan mapping 100 200
sonic(config-if-Ethernet1/1)# end
sonic# write memory
* Map a Double-Tagged VLAN Packet with Outer CVLAN 100 and Inner dot1q 200 to SVLAN 300 on Interface Eth1/2:
sonic# configure terminal
sonic(config)# interface Ethernet1/2
sonic(config-if-Ethernet1/2)# switchport mode trunk
sonic(config-if-Ethernet1/2)# switchport vlan mapping 100 200 300
sonic(config-if-Ethernet1/2)# end
sonic# write memory
Comprehensive Detailed Step by Step Explanation with References:
* Enter Configuration Mode:
* Access the global configuration mode using the configure terminal command.
* Configure Interface Eth1/1:
* Enter interface configuration mode for Ethernet1/1 using the command interface Ethernet1/1.
* Set the switchport mode to trunk with the command switchport mode trunk.
* Configure the VLAN translation using the switchport vlan mapping 100 200 command, which maps CVLAN 100 to SVLAN 200.
* Exit the interface configuration mode by typing end.
* Save the configuration with write memory.
* Configure Interface Eth1/2:
* Enter interface configuration mode for Ethernet1/2 using the command interface Ethernet1/2.
* Set the switchport mode to trunk with the command switchport mode trunk.
* Configure the double-tagged VLAN translation using the switchport vlan mapping 100 200 300 command, which maps packets with outer CVLAN 100 and inner dot1q 200 to SVLAN 300.
* Exit the interface configuration mode by typing end.
* Save the configuration with write memory.
References:
* Dell Technologies Networking - SONiC
* Dell Enterprise SONiC Deployment Guide
These steps provide a comprehensive guide to configure VLAN translations on a Dell SONiC switch, ensuring that the specific requirements for single-tagged and double-tagged VLAN mappings are met.
Which three actions are required to route traffic sourced from voice servers to a dedicated Internet link''

正解:B、C、D 解答を投票する
解説: (JPNTest メンバーにのみ表示されます)
What is the impact of entering the qos-mode uniform command on a VTEP interface?

解説: (JPNTest メンバーにのみ表示されます)
An administrator is installing Enterprise SONIC in ONIE from an HTTP server.
On which interface should the administrator configure the IP?

解説: (JPNTest メンバーにのみ表示されます)

弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

オンラインサポート時間:( UTC+9 ) 9:00-24:00
月曜日から土曜日まで

サポート:現在連絡